#1208 new Transmitter
06 12 19:25 Transmitter Power Measurements
Reported by: | ctipacti | Owned by: | somebody |
---|---|---|---|
Priority: | normal | Milestone: | 2023_06 Hybrid |
Component: | ISR | Version: | |
Keywords: | Cc: |
Description
07:54 LV ON
08:05 HV ON
08:20 TX Power Sample (-70 dB coupling)
TX1 4.20 Vpp
TX3 3.70 Vpp
Line Voltage 4070 VAC, 240 KW
09:00 TX Power Sample (-70 dB coupling)
TX1 4.10 Vpp
TX3 3.70 Vpp
Line Voltage 4070 VAC, 240 KW
10:00 TX Power Sample (-70 dB coupling)
TX1 4.10 Vpp
TX3 3.70 Vpp
Line Voltage 4070 VAC, 240 KW
11:00 PA1 Failure - Change to PA3
11:24 RF ON
12:00 TX Power Sample (-70 dB coupling)
TX3 3.80 Vpp
TX4 4.00 Vpp
Line Voltage 4050 VAC, 240 KW
12:52 DRV Bias power supply failure
13:10 RF ON
14:00 TX Power Sample (-70 dB coupling)
TX3 3.80 Vpp
TX4 4.00 Vpp
Line Voltage 4050 VAC, 250 KW
15:00 TX Power Sample (-70 dB coupling)
TX3 3.80 Vpp
TX4 4.00 Vpp
Line Voltage 4050 VAC, 250 KW
16:00 TX Power Sample (-70 dB coupling)
TX3 3.80 Vpp
TX4 4.00 Vpp
Line Voltage 4070 VAC, 250 KW
17:00 TX Power Sample (-70 dB coupling)
TX3 3.80 Vpp
TX4 4.00 Vpp
Line Voltage 4050 VAC, 250 KW
18:00 TX Power Sample (-70 dB coupling)
TX3 3.80 Vpp
TX4 4.00 Vpp
Line Voltage 4050 VAC, 250 KW
19:00 TX Power Sample (-70 dB coupling)
TX3 3.80 Vpp
TX4 4.00 Vpp
Line Voltage 4050 VAC, 250 KW