﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
1161	03 07 19:30 Transmitter report	ryaya	somebody	"09:00 TX Power Sample (-70 dB coupling)
TX1 5.30 Vpp
TX3 5.50 Vpp
Line Voltage 4100 VAC, 330 KW
10:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.60 Vpp
Line Voltage 4050 VAC, 330 KW
11:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.60 Vpp
Line Voltage 4010 VAC, 330 KW
12:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.60 Vpp
Line Voltage 4050 VAC, 330 KW
14:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.50 Vpp
Line Voltage 4000 VAC, 330 KW
15:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.50 Vpp
Line Voltage 4010 VAC, 330 KW
16:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.60 Vpp
Line Voltage 4020 VAC, 330 KW
17:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.60 Vpp
Line Voltage 4000 VAC, 330 KW
17:50 Night mode pulse configuration
18:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.60 Vpp
Line Voltage 4000 VAC, 330 KW
19:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX3 5.60 Vpp
Line Voltage 4000 VAC, 330 KW"	Transmitter	new	normal	2023_03 High Altitude Drifts	ISR				