﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
1099	02 01 07:00 Transmitter Report	ctipacti	somebody	"01/31/2023
20:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.9 Vpp
TX4 6.0 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 300 KW
21:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.9 Vpp
TX4 6.0 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 300 KW
22:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.9 Vpp
TX4 6.0 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 300 KW
23:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.9 Vpp
TX4 6.0 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 300 KW
02/01/2023
00:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.9 Vpp
TX4 6.0 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 300 KW
01:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.9 Vpp
TX4 6.0 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 300 KW
02:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.9 Vpp
TX4 6.0 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 300 KW
03:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.9 Vpp
TX4 6.0 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 300 KW
03:05 Falla controlador de radar
03:30 HV  OFF
04:10 HV  ON
04:15 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.9 Vpp
TX4 6.0 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 300 KW
05:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.8 Vpp
TX4 6.0 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 295 KW
06:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.8 Vpp
TX4 6.0 Vpp
Dr2 1.3 Vpp
Line Voltage 4050 VAC, 295 KW
06:15 Driver 2 OFF ""Imainging""
07:00 TX Power Sample (-70 dB coupling)
TX1 5.5 Vpp
TX3 5.8 Vpp
TX4 6.0 Vpp
Line Voltage 4050 VAC, 295 KW

"	Transmitter	new	normal	2023_01 ISR+Imaging	ISR				