Opened 17 months ago

#1091 new Transmitter

01 31 07:13 Transmitter report

Reported by: ctipacti Owned by: somebody
Priority: normal Milestone: 2023_01 ISR+Imaging
Component: ISR+Imaging Version:
Keywords: Cc:

Description

01/30/2023

20:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.80 Vpp
TX4 6.00 Vpp
Dr2 1.30 Vpp
Line Voltage 4020 VAC, 290 KW
21:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.80 Vpp
TX4 6.00 Vpp
Dr2 1.30 Vpp
Line Voltage 4050 VAC, 290 KW
22:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.80 Vpp
TX4 6.00 Vpp
Dr2 1.30 Vpp
Line Voltage 4020 VAC, 290 KW
23:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.80 Vpp
TX4 6.00 Vpp
Dr2 1.30 Vpp
Line Voltage 4050 VAC, 290 KW

01/31/2023

00:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.80 Vpp
TX4 6.00 Vpp
Dr2 1.30 Vpp
Line Voltage 4050 VAC, 290 KW
01:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.80 Vpp
TX4 6.00 Vpp
Dr2 1.30 Vpp
Line Voltage 4050 VAC, 290 KW
02:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.80 Vpp
TX4 6.00 Vpp
Dr2 1.30 Vpp
Line Voltage 4020 VAC, 290 KW
03:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.80 Vpp
TX4 6.00 Vpp
Dr2 1.30 Vpp
Line Voltage 4020 VAC, 290 KW
04:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.80 Vpp
TX4 6.00 Vpp
Dr2 1.30 Vpp
Line Voltage 4050 VAC, 290 KW
05:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.80 Vpp
TX4 6.00 Vpp
Dr2 1.30 Vpp
Line Voltage 4050 VAC, 290 KW
06:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.80 Vpp
TX4 6.00 Vpp
Dr2 1.30 Vpp
Line Voltage 4050 VAC, 290 KW
06:12 OFF Imaging
07:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.90 Vpp
TX4 6.10 Vpp
Line Voltage 4050 VAC, 290 KW

Change History (0)