﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
1083	01 30 2023 19:00 Transmitter Report	vquesada	somebody	"08:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.6 Vpp
TX4 5.8 Vpp
Line Voltage 4040 VAC, 280 KW
09:00 TX Power Sample (-70 dB coupling)
TX1 5.3 Vpp
TX3 5.6 Vpp
TX4 5.8 Vpp
Line Voltage 4040 VAC, 280 KW
09:30 HV OFF
09:57 HV ON
10:00 TX Power Sample (-70 dB coupling)
TX1 5.4 Vpp
TX3 5.9 Vpp
TX4 6.0 Vpp
Line Voltage 4040 VAC, 300 KW
11:00 TX Power Sample (-70 dB coupling)
TX1 5.4 Vpp
TX3 5.9 Vpp
TX4 6.0 Vpp
Line Voltage 4040 VAC, 300 KW
12:00 TX Power Sample (-70 dB coupling)
TX1 5.4 Vpp
TX3 5.9 Vpp
TX4 6.0 Vpp
Line Voltage 4080 VAC, 300 KW
13:00 TX Power Sample (-70 dB coupling)
TX1 5.4 Vpp
TX3 5.9 Vpp
TX4 6.0 Vpp
Line Voltage 4080 VAC, 300 KW
14:00 TX Power Sample (-70 dB coupling)
TX1 5.4 Vpp
TX3 5.9 Vpp
TX4 6.0 Vpp
Line Voltage 4080 VAC, 300 KW
15:00 TX Power Sample (-70 dB coupling)
TX1 5.4 Vpp
TX3 5.9 Vpp
TX4 6.0 Vpp
Line Voltage 4080 VAC, 300 KW
16:00 TX Power Sample (-70 dB coupling)
TX1 5.4 Vpp
TX3 5.9 Vpp
TX4 6.0 Vpp
Line Voltage 4080 VAC, 300 KW
17:00 TX Power Sample (-70 dB coupling)
TX1 5.4 Vpp
TX3 5.9 Vpp
TX4 6.0 Vpp
Line Voltage 4080 VAC, 300 KW
17:40 DRIVER 2 ON ""IMAGING""
18:00 TX Power Sample (-70 dB coupling)
TX1 5.4 Vpp
TX3 5.9 Vpp
TX4 6.0 Vpp
Dr2 1.3 Vpp
Line Voltage 4080 VAC, 300 KW
17:00 TX Power Sample (-70 dB coupling)
TX1 5.4 Vpp
TX3 5.9 Vpp
TX4 6.0 Vpp
Dr2 1.3 Vpp
Line Voltage 4080 VAC, 300 KW





"	Transmitter	new	normal	2023_01 ISR+Imaging	ISR				