﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
1067	01 29 07:36 Transmitter report	rtadeo	somebody	"
20:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.50 Vpp
TX4 5.90 Vpp
Dr2 1.20 Vpp
Line Voltage 4050 VAC, 290 KW
21:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.50 Vpp
TX4 5.90 Vpp
Dr2 1.20 Vpp
Line Voltage 4050 VAC, 290 KW
22:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.50 Vpp
TX4 5.90 Vpp
Dr2 1.20 Vpp
Line Voltage 4050 VAC, 290 KW
23:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.50 Vpp
TX4 5.90 Vpp
Dr2 1.20 Vpp
Line Voltage 4050 VAC, 290 KW
00:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.50 Vpp
TX4 5.90 Vpp
Dr2 1.20 Vpp
Line Voltage 4050 VAC, 290 KW
01:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.50 Vpp
TX4 5.90 Vpp
Dr2 1.20 Vpp
Line Voltage 4050 VAC, 290 KW
02:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.50 Vpp
TX4 5.60 Vpp
Dr2 1.30 Vpp
Line Voltage 4060 VAC, 280 KW
03:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.60 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4060 VAC, 280 KW
03:23 PA1 Screen Failure 
03:30 PA1 Screen Failure 
03:48 PA1 Screen Failure 
04:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.60 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4060 VAC, 280 KW
05:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.60 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4060 VAC, 280 KW
06:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.60 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4060 VAC, 280 KW
06:30 OFF Imaging
04:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.60 Vpp
TX4 5.90 Vpp
Line Voltage 4060 VAC, 280 KW
"	Transmitter	new	normal	2023_01 ISR+Imaging	ISR+Imaging				