1058	01 28 07:30 Transmitter report	rtadeo	somebody	"
20:00 TX Power Sample (-70 dB coupling)
TX1 5.60 Vpp
TX3 5.60 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4020 VAC, 290 KW
21:00 TX Power Sample (-70 dB coupling)
TX1 5.60 Vpp
TX3 5.60 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4020 VAC, 290 KW
22:00 TX Power Sample (-70 dB coupling)
TX1 5.60 Vpp
TX3 5.60 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4020 VAC, 290 KW
22:20 BIAS DRIVER3 FAILURE
00:30 RF ON
23:00 TX Power Sample (-70 dB coupling)
TX1 5.60 Vpp
TX3 5.60 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4020 VAC, 290 KW
01:00 TX Power Sample (-70 dB coupling)
TX1 5.40 Vpp
TX3 5.60 Vpp
TX4 5.90 Vpp
Dr2 1.30 Vpp
Line Voltage 4020 VAC, 290 KW
02:00 TX Power Sample (-70 dB coupling)
TX1 5.50 Vpp
TX3 5.80 Vpp
TX4 6.10 Vpp
Dr2 1.30 Vpp
Line Voltage 4020 VAC, 290 KW
03:00 TX Power Sample (-70 dB coupling)
TX1 5.50 Vpp
TX3 5.80 Vpp
TX4 6.10 Vpp
Dr2 1.30 Vpp
Line Voltage 4020 VAC, 290 KW
03.35 Crowbar +HV
04:00 TX Power Sample (-70 dB coupling)
TX1 5.50 Vpp
TX3 5.80 Vpp
TX4 6.10 Vpp
Dr2 1.30 Vpp
Line Voltage 4020 VAC, 290 KW
05:00 TX Power Sample (-70 dB coupling)
TX1 5.50 Vpp
TX3 5.80 Vpp
TX4 6.10 Vpp
Dr2 1.30 Vpp
Line Voltage 4020 VAC, 290 KW
06:00 TX Power Sample (-70 dB coupling)
TX1 5.50 Vpp
TX3 5.80 Vpp
TX4 6.10 Vpp
Dr2 1.30 Vpp
Line Voltage 4020 VAC, 290 KW
06:40 OFF TX Imaging
07:00 TX Power Sample (-70 dB coupling)
TX1 5.50 Vpp
TX3 5.80 Vpp
TX4 6.10 Vpp
Line Voltage 4020 VAC, 290 KW
"	Transmitter	new	normal	2023_01 ISR+Imaging	ISR+Imaging				