Opened 4 years ago

#101 new Transmitter

01 12 19:15 Transmitter report

Reported by: ctipacti Owned by: somebody
Priority: normal Milestone: 2021_01 Valley9
Component: ISR Version:
Keywords: Cc:

Description

05:43 LV ON
06:15 HV ON
06:30 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX4 5.20 Vpp
Line Voltage 4050 VAC, 310 KW
07:00 TX Power Sample (-70 dB coupling)
TX1 5.30 Vpp
TX4 5.20 Vpp
Line Voltage 4050 VAC, 310 KW
08:00 TX Power Sample (-70 dB coupling)
TX1 5.30 Vpp
TX4 5.10 Vpp
Line Voltage 4000 VAC, 310 KW
09:00 TX Power Sample (-70 dB coupling)
TX1 5.30 Vpp
TX4 5.10 Vpp
Line Voltage 4020 VAC, 320 KW
10:00 TX Power Sample (-70 dB coupling)
TX1 5.30 Vpp
TX4 5.10 Vpp
Line Voltage 4020 VAC, 320 KW
11:00 TX Power Sample (-70 dB coupling)
TX1 5.30 Vpp
TX4 5.10 Vpp
Line Voltage 4050 VAC, 320 KW
11:12 PA1 Screen Power Supply failure
12:00 TX Power Sample (-70 dB coupling)
TX1 5.30 Vpp
TX4 5.10 Vpp
Line Voltage 4020 VAC, 320 KW
14:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX4 5.10 Vpp
Line Voltage 4000 VAC, 320 KW
15:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX4 5.10 Vpp
Line Voltage 4000 VAC, 320 KW
15:53 PA1 Screen Power Supply failure
16:00 TX Power Sample (-70 dB coupling)
TX1 5.30 Vpp
TX4 5.10 Vpp
Line Voltage 4050 VAC, 320 KW
17:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX4 5.10 Vpp
Line Voltage 4000 VAC, 320 KW
18:00 TX Power Sample (-70 dB coupling)
TX1 5.30 Vpp
TX4 5.10 Vpp
Line Voltage 4050 VAC, 320 KW
19:00 TX Power Sample (-70 dB coupling)
TX1 5.20 Vpp
TX4 5.10 Vpp
Line Voltage 4000 VAC, 320 KW

Change History (0)