Opened 6 years ago
#983 new Transmitter
03 27 07:07 Transmitter Power Measurements
Reported by: | vquesada | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2019_03 ISR+Imaging (CONGSS-19) |
Component: | ISR | Version: | |
Keywords: | Cc: |
Description
MARCH 26
20:00 TX Power sample (-70 dB coupling)
TX1 5.72 Vpp
TX3 5.80 Vpp
TX4 5.56 Vpp
Dr2 1.34 Vpp
Line Voltage 4080 VAC, 290 KW
21:00 TX Power sample (-70 dB coupling)
TX1 5.72 Vpp
TX3 5.80 Vpp
TX4 5.56 Vpp
Dr2 1.34 Vpp
Line Voltage 4080 VAC, 290 KW
22:00 TX Power sample (-70 dB coupling)
TX1 5.72 Vpp
TX3 5.80 Vpp
TX4 5.56 Vpp
Dr2 1.34 Vpp
Line Voltage 4080 VAC, 290 KW
23:00 TX Power sample (-70 dB coupling)
TX1 5.72 Vpp
TX3 5.80 Vpp
TX4 5.56 Vpp
Dr2 1.34 Vpp
Line Voltage 4080 VAC, 290 KW
MARCH 27
00:00 TX Power sample (-70 dB coupling)
TX1 5.72 Vpp
TX3 5.80 Vpp
TX4 5.56 Vpp
Dr2 1.34 Vpp
Line Voltage 4080 VAC, 290 KW
01:00 TX Power sample (-70 dB coupling)
TX1 5.72 Vpp
TX3 5.80 Vpp
TX4 5.56 Vpp
Dr2 1.34 Vpp
Line Voltage 4080 VAC, 290 KW
02:00 TX Power sample (-70 dB coupling)
TX1 5.72 Vpp
TX3 5.80 Vpp
TX4 5.56 Vpp
Dr2 1.34 Vpp
Line Voltage 4060 VAC, 290 KW
03:00 TX Power sample (-70 dB coupling)
TX1 5.72 Vpp
TX3 5.80 Vpp
TX4 5.56 Vpp
Dr2 1.34 Vpp
Line Voltage 4060 VAC, 290 KW
04:00 TX Power sample (-70 dB coupling)
TX1 5.72 Vpp
TX3 5.80 Vpp
TX4 5.56 Vpp
Dr2 1.34 Vpp
Line Voltage 4060 VAC, 290 KW
05:00 TX Power sample (-70 dB coupling)
TX1 5.72 Vpp
TX3 5.80 Vpp
TX4 5.56 Vpp
Dr2 1.34 Vpp
Line Voltage 4060 VAC, 290 KW
06:00 TX Power sample (-70 dB coupling)
TX1 5.72 Vpp
TX3 5.80 Vpp
TX4 5.56 Vpp
Dr2 1.34 Vpp
Line Voltage 4080 VAC, 290 KW
06:10 DRIVER 2 OFF
07:00 TX Power sample (-70 dB coupling)
TX1 5.72 Vpp
TX3 5.80 Vpp
TX4 5.56 Vpp
Line Voltage 4080 VAC, 290 KW