Opened 5 years ago

#920 new Transmitter

03 07 17:35 Transmitter Power Measurements

Reported by: ctipacti Owned by:
Priority: normal Milestone: 2019_03 MST-ISR-EEJ
Component: ISR Version:
Keywords: Cc:

Description

09:00 TX Power sample (-70 dB coupling)
Tx1 5.32 Vpp
Tx4 5.28 Vpp
Voltage Line: 4050 VAC, 260 KW
10:00 TX Power sample (-70 dB coupling)
Tx1 5.32 Vpp
Tx4 5.32 Vpp
Voltage Line: 4050 VAC, 260 KW
11:00 TX Power sample (-70 dB coupling)
Tx1 5.28 Vpp
Tx4 5.24 Vpp
Voltage Line: 4050 VAC, 260 KW
12:00 TX Power sample (-70 dB coupling)
Tx1 5.20 Vpp
Tx4 5.20 Vpp
Voltage Line: 4050 VAC, 260 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 5.18 Vpp
Tx4 5.12 Vpp
Voltage Line: 4000 VAC, 260 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 5.16 Vpp
Tx4 5.12 Vpp
Voltage Line: 4000 VAC, 260 KW
15:42 PA1 Screen power supply failure
16:00 TX Power sample (-70 dB coupling)
Tx1 5.20 Vpp
Tx4 5.20 Vpp
Voltage Line: 4070 VAC, 260 KW
16:04 PA1 Screen power supply failure
17:00 TX Power sample (-70 dB coupling)
Tx1 5.20 Vpp
Tx4 5.20 Vpp
Voltage Line: 4020 VAC, 260 KW
17:30 HV OFF
17:45 LV OFF

Change History (0)