02 06 07:00 Transmitter Power Measurements
Reported by: | vquesada | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2019_02 ISR+Imaging (Bubbles) |
Component: | ISR | Version: | |
Keywords: | Cc: |
Description
February 05
20:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.8 Vpp
Tx4 5.6 Vpp
Dr2 1.4 Vpp
Voltage Line: 4050 VAC, 280 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.8 Vpp
Tx4 5.6 Vpp
Dr2 1.4 Vpp
Voltage Line: 4050 VAC, 280 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.8 Vpp
Tx4 5.7 Vpp
Dr2 1.4 Vpp
Voltage Line: 4100 VAC, 290 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.8 Vpp
Tx4 5.7 Vpp
Dr2 1.4 Vpp
Voltage Line: 4100 VAC, 290 KW
February 06
00:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.8 Vpp
Tx4 5.8 Vpp
Dr2 1.4 Vpp
Voltage Line: 4060 VAC, 280 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.8 Vpp
Tx4 5.8 Vpp
Dr2 1.4 Vpp
Voltage Line: 4060 VAC, 280 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.8 Vpp
Tx4 5.8 Vpp
Dr2 1.4 Vpp
Voltage Line: 4080 VAC, 280 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.8 Vpp
Tx4 5.8 Vpp
Dr2 1.4 Vpp
Voltage Line: 4060 VAC, 280 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.8 Vpp
Tx4 5.8 Vpp
Dr2 1.4 Vpp
Voltage Line: 4060 VAC, 280 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.8 Vpp
Tx4 5.8 Vpp
Dr2 1.4 Vpp
Voltage Line: 4060 VAC, 280 KW
06:05 Driver 2 OFF
6:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.8 Vpp
Tx4 5.7 Vpp
Voltage Line: 4060 VAC, 280 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.8 Vpp
Tx4 5.7 Vpp
Voltage Line: 4060 VAC, 280 Kw