Opened 6 years ago

#837 new Transmitter

02 03 19:30 Transmitter power measurements

Reported by: ryaya Owned by:
Priority: normal Milestone: 2019_02 ISR+Imaging (Bubbles)
Component: ISR+Imaging Version:
Keywords: Cc:

Description

08:1o Second blower on
08:30 Dr4 airflow swith failure
09:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.6 Vpp
Tx4 5.5 Vpp
Voltage Line: 4060 VAC, 290 KW
10:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.6 Vpp
Tx4 5.5 Vpp
Voltage Line: 4050 VAC, 260 KW
11:03 PA1 Screen power supply failure
11:05 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.6 Vpp
Tx4 5.5 Vpp
Voltage Line: 4020 VAC, 290 KW
12:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.6 Vpp
Tx4 5.5 Vpp
Voltage Line: 4050 VAC, 290 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.6 Vpp
Tx4 5.5 Vpp
Voltage Line: 4030 VAC, 290 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.7 Vpp
Tx4 5.5 Vpp
Voltage Line: 4050 VAC, 290 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.6 Vpp
Tx4 5.5 Vpp
Voltage Line: 4010 VAC, 290 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.6 Vpp
Tx4 5.5 Vpp
Voltage Line: 4030 VAC, 290 KW
17:36 D2 ON " Imaging"
18:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.6 Vpp
Tx4 5.5 Vpp
D2 1.4 Vpp
Voltage Line: 4000 VAC, 290 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.6 Vpp
Tx4 5.5 Vpp
D2 1.4 Vpp
Voltage Line: 4020 VAC, 290 Kw