Opened 6 years ago

#823 new Transmitter

02 02 19:30 Transmitter power measurements

Reported by: ryaya Owned by:
Priority: normal Milestone: 2019_02 ISR+Imaging (Bubbles)
Component: ISR+Imaging Version:
Keywords: Cc:

Description

07:55 LV ON
08:15 HV ON
09:00 TX Power sample (-70 dB coupling)
Tx1 6.0 Vpp
Tx3 5.8 Vpp
Tx4 5.6 Vpp
Voltage Line: 4030 VAC, 260 KW
10:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.7 Vpp
Tx4 5.5 Vpp
Voltage Line: 4020 VAC, 260 KW
11:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.7 Vpp
Tx4 5.6 Vpp
Voltage Line: 4080 VAC, 290 KW - Second blower on
12:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.8 Vpp
Tx4 5.6 Vpp
Voltage Line: 4030 VAC, 290 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.7 Vpp
Tx4 5.6 Vpp
Voltage Line: 4010 VAC, 290 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.7 Vpp
Tx4 5.6 Vpp
Voltage Line: 4000 VAC, 290 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.8 Vpp
Tx4 5.6 Vpp
Voltage Line: 4020 VAC, 290 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.8 Vpp
Tx4 5.6 Vpp
Voltage Line: 4010 VAC, 260 KW - second blower off
17:30 D2 ON " Imaging"
18:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.9 Vpp
Tx4 5.6 Vpp
D2 1.3 Vpp
Voltage Line: 4080 VAC, 260 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.7 Vpp
Tx4 5.6 Vpp
D2 1.3 Vpp
Voltage Line: 4030 VAC, 270 Kw

Change History (1)

comment:1 Changed 7 years ago by kkuyeng

  • Milestone changed from 2018_02_1 ISR + Imaging to 2019_02 ISR+Imaging (Bubbles)