﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
771	01 06 07:40 Transmitter power measurement	ryaya		"21:00 Failure at PLC control system
21:14 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2  1.3 Vpp
Voltage Line: 4060 VAC, 230 Kw
22:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2  1.3 Vpp
Voltage Line: 4060 VAC, 230 Kw
23:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2  1.3 Vpp
Voltage Line: 4080 VAC, 230 Kw
January 06
00:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2  1.3 Vpp
Voltage Line: 4060 VAC, 230 Kw
01:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
D2  1.3 Vpp
Voltage Line: 4100 VAC, 230 Kw
02:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2  1.3 Vpp
Voltage Line: 4080 VAC, 230 Kw
03:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2  1.3 Vpp
Voltage Line: 4080 VAC, 230 Kw
04:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2  1.3 Vpp
Voltage Line: 4080 VAC, 230 Kw
05:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2  1.3 Vpp
Voltage Line: 4060 VAC, 230 Kw
06:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2  1.3 Vpp
Voltage Line: 4050 VAC, 230 Kw
06:10 Driver 2 OFF
07:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Voltage Line: 4100 VAC, 230 Kw"	Transmitter	new	normal	2019_01 ISR+Imaging (SSW)	ISR+Imaging				