Opened 6 years ago
#763 new Transmitter
01 05 07:15 Transmitter Power Measurements
Reported by: | vquesada | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2019_01 ISR+Imaging (SSW) |
Component: | ISR | Version: | |
Keywords: | Cc: |
Description
January 04
20:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2 1.3 Vpp
Voltage Line: 4060 VAC, 240 Kw
21:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2 1.3 Vpp
Voltage Line: 4060 VAC, 240 Kw
22:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2 1.3 Vpp
Voltage Line: 4050 VAC, 240 Kw
23:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2 1.3 Vpp
Voltage Line: 4050 VAC, 240 Kw
January 05
00:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2 1.3 Vpp
Voltage Line: 4060 VAC, 240 Kw
01:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2 1.3 Vpp
Voltage Line: 4060 VAC, 240 Kw
02:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2 1.3 Vpp
Voltage Line: 4060 VAC, 240 Kw
03:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2 1.3 Vpp
Voltage Line: 4060 VAC, 240 Kw
04:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2 1.3 Vpp
Voltage Line: 4060 VAC, 240 Kw
05:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2 1.3 Vpp
Voltage Line: 4060 VAC, 240 Kw
06:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2 1.3 Vpp
Voltage Line: 4060 VAC, 240 Kw
06:01 Driver 2 OFF
70:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
D2 1.3 Vpp
Voltage Line: 4060 VAC, 240 Kw