Opened 6 years ago
#747 new Transmitter
01 04 02:45 Transmitter Power Measurements
Reported by: | vquesada | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2019_01 ISR+Imaging (SSW) |
Component: | ISR | Version: | |
Keywords: | Cc: |
Description
January 03
20:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
Tx3 5.8 Vpp
Tx4 5.7 Vpp
D2 1.3 Vpp
Voltage Line: 4080 VAC, 280 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
Tx3 5.8 Vpp
Tx4 5.7 Vpp
D2 1.3 Vpp
Voltage Line: 4080 VAC, 280 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
Tx3 5.8 Vpp
Tx4 5.7 Vpp
D2 1.3 Vpp
Voltage Line: 4080 VAC, 280 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
Tx3 5.8 Vpp
Tx4 5.7 Vpp
D2 1.3 Vpp
Voltage Line: 4080 VAC, 280 KW
January 04
00:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
Tx3 5.8 Vpp
Tx4 5.7 Vpp
D2 1.2 Vpp
Voltage Line: 4080 VAC, 280 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
Tx3 5.8 Vpp
Tx4 5.7 Vpp
D2 1.2 Vpp
Voltage Line: 4080 VAC, 280 KW
01:10 HV OFF (Tx3 high pressure hose failure)