Opened 6 years ago

#731 new Transmitter

01 02 19:20 Transmitter power measurements

Reported by: ryaya Owned by:
Priority: normal Milestone: 2019_01 ISR+Imaging (SSW)
Component: ISR+Imaging Version:
Keywords: Cc:

Description

08:30 LV ON
09:00 HV ON
09:10 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
Tx3 5.9 Vpp
Tx4 5.8 Vpp
Voltage Line: 4100 VAC, 280 KW
10:00 TX Power sample (-70 dB coupling)
Tx1 5.5 Vpp
Tx3 5.7 Vpp
Tx4 5.8 Vpp
Voltage Line: 4060 VAC, 280 KW
11:00 TX Power sample (-70 dB coupling)
Tx1 5.5 Vpp
Tx3 5.7 Vpp
Tx4 5.8 Vpp
Voltage Line: 4030 VAC, 280 KW
12:00 TX Power sample (-70 dB coupling)
Tx1 5.5 Vpp
Tx3 5.7 Vpp
Tx4 5.8 Vpp
Voltage Line: 4080 VAC, 280 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 5.5 Vpp
Tx3 5.7 Vpp
Tx4 5.8 Vpp
Voltage Line: 4080 VAC, 280 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 5.5 Vpp
Tx3 5.7 Vpp
Tx4 5.8 Vpp
Voltage Line: 4050 VAC, 280 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 5.5 Vpp
Tx3 5.8 Vpp
Tx4 5.8 Vpp
Voltage Line: 4060 VAC, 280 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 5.5 Vpp
Tx3 5.7 Vpp
Tx4 5.8 Vpp
Voltage Line: 4090 VAC, 280 KW
17:28 D2 ON " Imaging"
18:00 TX Power sample (-70 dB coupling)
Tx1 5.5 Vpp
Tx3 5.7 Vpp
Tx4 5.7 Vpp
D2 1.3 Vpp
Voltage Line: 4030 VAC, 280 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
Tx3 5.8 Vpp
Tx4 5.7 Vpp
D2 1.3 Vpp
Voltage Line: 4060 VAC, 280 Kw

Change History (0)