Opened 7 years ago

#7 new Transmitter

11 Jan 07:15 Transmitter Power Measurements

Reported by: rtadeo Owned by:
Priority: normal Milestone: 2018_01 ISR + Imaging
Component: ISR+Imaging Version:
Keywords: Cc:

Description

10/01/2018
20:00 TX Power sample (-70 dB coupling)
Tx1 6.08 Vpp
Tx3 6.16 Vpp
Tx4 6.30 Vpp
Dr2 1.46 Vpp
Line voltage and power: 4050 VAC, 260 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 6.08 Vpp
Tx3 6.16 Vpp
Tx4 6.30 Vpp
Dr2 1.46 Vpp
Line voltage and power: 4050 VAC, 260 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 6.00 Vpp
Tx3 6.16 Vpp
Tx4 6.32 Vpp
Dr2 1.48 Vpp
Line voltage and power: 4050 VAC, 260 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 6.04 Vpp
Tx3 6.12 Vpp
Tx4 6.32 Vpp
Dr2 1.48 Vpp
Line voltage and power: 4050 VAC, 260 KW
11/01/2018
00:00 TX Power sample (-70 dB coupling)
Tx1 6.04 Vpp
Tx3 6.12 Vpp
Tx4 6.32 Vpp
Dr2 1.48 Vpp
Line voltage and power: 4060 VAC, 260 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 6.04 Vpp
Tx3 6.12 Vpp
Tx4 6.30 Vpp
Dr2 1.48 Vpp
Line voltage and power: 4060 VAC, 260 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 6.04 Vpp
Tx3 6.12 Vpp
Tx4 6.30 Vpp
Dr2 1.48 Vpp
Line voltage and power: 4060 VAC, 260 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 924 Kw
Tx3 930 Kw
Tx4 936 Kw
Dr2 53 Kw
Line voltage and power: 4070 VAC, 280 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 924 Kw
Tx3 936 Kw
Tx4 936 Kw
Dr2 53 Kw
Line voltage and power: 4070 VAC, 280 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 924 Kw
Tx3 936 Kw
Tx4 936 Kw
Dr2 53 Kw
Line voltage and power: 4070 VAC, 280 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 924 Kw
Tx3 936 Kw
Tx4 936 Kw
Dr2 53 Kw
Line voltage and power: 4070 VAC, 280 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 924 Kw
Tx3 936 Kw
Tx4 936 Kw
Dr2 53 Kw
Line voltage and power: 4070 VAC, 280 KW