Opened 6 years ago

Last modified 6 years ago

#666 new Transmitter

12 08 08:00 Transmitter report

Reported by: ryaya Owned by:
Priority: normal Milestone: 2018_12 ISR+Imaging + HF
Component: ISR+Imaging Version:
Keywords: Cc:

Description

07/12/2018
21:00 TX Power sample (-70 dB coupling)
Tx1 5.9 Vpp
Tx3 5.9 Vpp
Tx4 5.7 Vpp
Dr2 1.3 Vpp
Voltage Line: 4080 VAC, 290 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 5.9 Vpp
Tx3 5.9 Vpp
Tx4 5.8 Vpp
Dr2 1.3 Vpp
Voltage Line: 4080 VAC, 290 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 5.9 Vpp
Tx3 5.9 Vpp
Tx4 5.7 Vpp
Dr2 1.3 Vpp
Voltage Line: 4040 VAC, 290 KW
07/12/2018
00:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.9 Vpp
Tx4 5.8 Vpp
Dr2 1.3 Vpp
Voltage Line: 4030 VAC, 290 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.9 Vpp
Tx4 5.7 Vpp
Dr2 1.3 Vpp
Voltage Line: 4050 VAC, 290 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.9 Vpp
Tx4 5.8 Vpp
Dr2 1.3 Vpp
Voltage Line: 4080 VAC, 290 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.9 Vpp
Tx4 5.8 Vpp
Dr2 1.3 Vpp
Voltage Line: 4080 VAC, 290 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.9 Vpp
Tx4 5.8 Vpp
Dr2 1.3 Vpp
Voltage Line: 4090 VAC, 290 KW
05:00 Problem with TX1, fault on filament power supply.
05:30 TX1 and TX4 were deactivated due to failure in TX1.
06:00 TX Power sample (-70 dB coupling)
Tx3 5.8 Vpp
Dr2 1.3
Voltage Line: 4090 VAC, 240 KW
06:30 D2 OFF
07:00 TX Power sample (-70 dB coupling)
Tx3 5.9 Vpp
Voltage Line: 4100 VAC, 240 KW
08:00 HV OFF
08:15 LV OFF

Change History (1)

comment:1 Changed 6 years ago by ryaya

  • Summary changed from 12 06 08:00 Transmitter report to 12 08 08:00 Transmitter report
Note: See TracTickets for help on using tickets.