Opened 6 years ago

#657 new Transmitter

12 07 19:30 Transmitter power measurements

Reported by: rtadeo Owned by:
Priority: normal Milestone: 2018_12 ISR+Imaging + HF
Component: ISR+Imaging Version:
Keywords: Cc:

Description

07/12/2018
08:00 TX Power sample (-70 dB coupling)
Tx1 5.76 Vpp
Tx3 5.84 Vpp
Tx4 5.72 Vpp
Voltage Line: 4050 VAC, 290 KW
09:00 TX Power sample (-70 dB coupling)
Tx1 5.76 Vpp
Tx3 5.84 Vpp
Tx4 5.72 Vpp
Voltage Line: 4050 VAC, 290 KW
10:00 TX Power sample (-70 dB coupling)
Tx1 5.76 Vpp
Tx3 5.84 Vpp
Tx4 5.72 Vpp
Voltage Line: 4050 VAC, 290 KW
11:00 TX Power sample (-70 dB coupling)
Tx1 5.64 Vpp
Tx3 5.72 Vpp
Tx4 5.72 Vpp
Voltage Line: 4050 VAC, 290 KW
12:00 TX Power sample (-70 dB coupling)
Tx1 5.64 Vpp
Tx3 5.84 Vpp
Tx4 5.76 Vpp
Voltage Line: 4030 VAC, 290 KW
13:00 TX Power sample (-70 dB coupling)
Tx1 5.64 Vpp
Tx3 5.76 Vpp
Tx4 5.76 Vpp
Voltage Line: 4030 VAC, 290 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 5.64 Vpp
Tx3 5.76 Vpp
Tx4 5.76 Vpp
Voltage Line: 4030 VAC, 290 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 5.64 Vpp
Tx3 5.76 Vpp
Tx4 5.76 Vpp
Voltage Line: 4030 VAC, 290 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 5.64 Vpp
Tx3 5.76 Vpp
Tx4 5.76 Vpp
Voltage Line: 4030 VAC, 290 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 5.64 Vpp
Tx3 5.80 Vpp
Tx4 5.80 Vpp
Voltage Line: 4030 VAC, 290 KW
18:00 off Imaging
18:00 TX Power sample (-70 dB coupling)
Tx1 5.72 Vpp
Tx3 5.84 Vpp
Tx4 5.72 Vpp
Dr2 1.30 Vpp
Voltage Line: 4040 VAC, 300 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 5.92 Vpp
Tx3 5.84 Vpp
Tx4 5.68 Vpp
Dr2 1.35 Vpp
Voltage Line: 4030 VAC, 290 KW

Change History (0)