605	11 08 07:15 Transmitter Power Measurements	rtadeo		"20:00 TX Power sample (-70 dB coupling)
Tx1 5.84 Vpp
Tx2 5.56 Vpp
Tx4 5.68 Vpp
Dr2 1.42 Vpp
Voltage Line: 4100 VAC, 280 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 5.84 Vpp
Tx2 5.56 Vpp
Tx4 5.68 Vpp
Dr2 1.42 Vpp
Voltage Line: 4100 VAC, 280 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 5.80 Vpp
Tx2 5.56 Vpp
Tx4 5.60 Vpp
Dr2 1.43 Vpp
Voltage Line: 4050 VAC, 270 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 5.80 Vpp
Tx2 5.56 Vpp
Tx4 5.60 Vpp
Dr2 1.43 Vpp
Voltage Line: 4050 VAC, 270 KW
00:00 TX Power sample (-70 dB coupling)
Tx1 5.80 Vpp
Tx2 5.56 Vpp
Tx4 5.60 Vpp
Dr2 1.44 Vpp
Voltage Line: 4050 VAC, 270 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 5.80 Vpp
Tx2 5.56 Vpp
Tx4 5.60 Vpp
Dr2 1.44 Vpp
Voltage Line: 4050 VAC, 270 KW
01:03 Screen failure of the TX4 and Dr1
02:00 TX Power sample (-70 dB coupling)
Tx1 5.80 Vpp
Tx2 5.56 Vpp
Tx4 5.60 Vpp
Dr2 1.44 Vpp
Voltage Line: 4050 VAC, 270 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 5.80 Vpp
Tx2 5.56 Vpp
Tx4 5.60 Vpp
Dr2 1.44 Vpp
Voltage Line: 4050 VAC, 270 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 5.68 Vpp
Tx2 5.64 Vpp
Tx4 5.72 Vpp
Dr2 1.44 Vpp
Voltage Line: 4050 VAC, 270 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 5.68 Vpp
Tx2 5.64 Vpp
Tx4 5.72 Vpp
Dr2 1.44 Vpp
Voltage Line: 4050 VAC, 270 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 5.68 Vpp
Tx2 5.64 Vpp
Tx4 5.72 Vpp
Dr2 1.44 Vpp
Voltage Line: 4050 VAC, 270 KW
06:03 Imaging OFF
07:00 TX Power sample (-70 dB coupling)
Tx1 5.68 Vpp
Tx2 5.56 Vpp
Tx4 5.72 Vpp
Voltage Line: 4050 VAC, 270 KW
"	Transmitter	new	normal	2018_11 ISR+Imaging + HF	ISR+Imaging				