Opened 6 years ago
#558 new Transmitter
10 02 19:30 Transmitter measurements
Reported by: | ryaya | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2018_10 ISR+Imaging + HF |
Component: | ISR+Imaging | Version: | |
Keywords: | Cc: |
Description
09:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.9 Vpp
Tx4 5.6 Vpp
Voltage Line: 4060 VAC, 280 KW
10:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.9 Vpp
Tx4 5.6 Vpp
Voltage Line: 4070 VAC, 280 KW
11:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.9 Vpp
Tx4 5.6 Vpp
Voltage Line: 4010 VAC, 280 KW
12:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
Tx3 5.8 Vpp
Tx4 5.6 Vpp
Voltage Line: 4050 VAC, 280 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 5.5 Vpp
Tx3 5.8 Vpp
Tx4 5.5 Vpp
Voltage Line: 4000 VAC, 280 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.9 Vpp
Tx4 5.6 Vpp
Voltage Line: 4070 VAC, 280 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.8 Vpp
Tx4 5.6 Vpp
Voltage Line: 4020 VAC, 280 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
Tx3 5.8 Vpp
Tx4 5.5 Vpp
Voltage Line: 4010 VAC, 280 KW
17:30 Drive 2 ON "IMAGING"
18:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.9 Vpp
Tx4 5.5 Vpp
D2 1.28 Vpp
Voltage Line: 4040 VAC, 280 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.9 Vpp
Tx4 5.5 Vpp
D2 1.3 Vpp
Voltage Line: 4060 VAC, 280 KW