Opened 6 years ago

#551 new Transmitter

10 02 07:20 Transmitter Power Measurements

Reported by: rtadeo Owned by:
Priority: normal Milestone: 2018_10 ISR+Imaging + HF
Component: ISR+Imaging Version:
Keywords: Cc:

Description

20:00 TX Power sample (-70 dB coupling)
Tx1 5.60 Vpp
Tx3 5.80 Vpp
Tx4 5.60 Vpp
Dr2 1.33 Vpp
Voltage Line: 4080 VAC, 280 KW
21:00 TX Power sample (-70 dB coupling)
Tx1 5.60 Vpp
Tx3 5.80 Vpp
Tx4 5.60 Vpp
Dr2 1.33 Vpp
Voltage Line: 4080 VAC, 280 KW
22:00 TX Power sample (-70 dB coupling)
Tx1 5.68 Vpp
Tx3 6.04 Vpp
Tx4 5.60 Vpp
Dr2 1.37 Vpp
Voltage Line: 4050 VAC, 280 KW
23:00 TX Power sample (-70 dB coupling)
Tx1 5.68 Vpp
Tx3 6.04 Vpp
Tx4 5.60 Vpp
Dr2 1.37 Vpp
Voltage Line: 4050 VAC, 280 KW
00:00 TX Power sample (-70 dB coupling)
Tx1 5.68 Vpp
Tx3 6.04 Vpp
Tx4 5.60 Vpp
Dr2 1.37 Vpp
Voltage Line: 4050 VAC, 280 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 5.68 Vpp
Tx3 6.04 Vpp
Tx4 5.60 Vpp
Dr2 1.37 Vpp
Voltage Line: 4050 VAC, 280 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 5.68 Vpp
Tx3 6.04 Vpp
Tx4 5.60 Vpp
Dr2 1.37 Vpp
Voltage Line: 4050 VAC, 280 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 5.76 Vpp
Tx3 6.04 Vpp
Tx4 5.60 Vpp
Dr2 1.40 Vpp
Voltage Line: 4050 VAC, 280 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 5.76 Vpp
Tx3 6.04 Vpp
Tx4 5.60 Vpp
Dr2 1.40 Vpp
Voltage Line: 4050 VAC, 280 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 5.76 Vpp
Tx3 6.04 Vpp
Tx4 5.60 Vpp
Dr2 1.40 Vpp
Voltage Line: 4050 VAC, 280 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 5.76 Vpp
Tx3 6.04 Vpp
Tx4 5.60 Vpp
Dr2 1.40 Vpp
Voltage Line: 4050 VAC, 280 KW
07:00 TX Power sample (-70 dB coupling)
Tx1 5.68 Vpp
Tx3 6.00 Vpp
Tx4 5.50 Vpp
Dr2 1.38 Vpp
Voltage Line: 4050 VAC, 280 KW
07:20 OFF IMAGING

Change History (0)

Note: See TracTickets for help on using tickets.