Opened 6 years ago
Last modified 6 years ago
#528 new Transmitter
09 25 07:00 Transmitter Power Measurements
Reported by: | vquesada | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2018_09_3 ISCOD ISR+Imaging |
Component: | ISR | Version: | |
Keywords: | Cc: |
Description
00:00 TX Power sample (-70 dB coupling)
Tx1 5.52 Vpp
Tx3 5.76 Vpp
Tx4 5.32 Vpp
Dr2 1.35Vpp
Voltage Line: 4050 VAC, 280 KW
01:00 TX Power sample (-70 dB coupling)
Tx1 5.52 Vpp
Tx3 5.76 Vpp
Tx4 5.32 Vpp
Dr2 1.35Vpp
Voltage Line: 4050 VAC, 280 KW
02:00 TX Power sample (-70 dB coupling)
Tx1 5.52 Vpp
Tx3 5.76 Vpp
Tx4 5.32 Vpp
Dr2 1.35Vpp
Voltage Line: 4050 VAC, 280 KW
03:00 TX Power sample (-70 dB coupling)
Tx1 5.52 Vpp
Tx3 5.76 Vpp
Tx4 5.32 Vpp
Dr2 1.35Vpp
Voltage Line: 4050 VAC, 280 KW
04:00 TX Power sample (-70 dB coupling)
Tx1 5.52 Vpp
Tx3 5.76 Vpp
Tx4 5.44 Vpp
Dr2 1.35Vpp
Voltage Line: 4060 VAC, 280 KW
05:00 TX Power sample (-70 dB coupling)
Tx1 5.52 Vpp
Tx3 5.76 Vpp
Tx4 5.44 Vpp
Dr2 1.35Vpp
Voltage Line: 4060 VAC, 280 KW
06:00 TX Power sample (-70 dB coupling)
Tx1 5.52 Vpp
Tx3 5.76 Vpp
Tx4 5.44 Vpp
Dr2 1.35Vpp
Voltage Line: 4060 VAC, 280 KW
06:30 DRIVER 2 OFF
07:00 TX Power sample (-70 dB coupling)
Tx1 5.52 Vpp
Tx3 5.76 Vpp
Tx4 5.44 Vpp
Dr2 1.35Vpp
Voltage Line: 4060 VAC, 280 KW
Change History (1)
comment:1 Changed 6 years ago by ryanque
- Summary changed from 9 25 07:00 Transmitter Power Measurements to 09 25 07:00 Transmitter Power Measurements