Opened 6 years ago
#509 new Transmitter
09 23 19:30 Transmitter report
Reported by: | ryaya | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2018_09_3 ISCOD ISR+Imaging |
Component: | ISR+Imaging | Version: | |
Keywords: | Cc: |
Description
08:00 HV OFF-Failure detected on main plate power supply
09:00 HV ON
09:00 TX Power sample (-70 dB coupling)
Tx1 5.5 Vpp
Tx3 5.8 Vpp
Tx4 5.5 Vpp
Voltage Line: 4090 VAC 280 KW
10:00 TX Power sample (-70 dB coupling)
Tx1 5.5 Vpp
Tx3 5.9 Vpp
Tx4 5.6 Vpp
Voltage Line: 4080 VAC 280 KW
11:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.8 Vpp
Tx4 5.6 Vpp
Voltage Line: 4050 VAC 280 KW
12:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
Tx3 5.8 Vpp
Tx4 5.7 Vpp
Voltage Line: 4080 VAC 280 KW
13:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
Tx3 5.7 Vpp
Tx4 5.7 Vpp
Voltage Line: 4060 VAC 280 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
Tx3 5.8 Vpp
Tx4 5.8 Vpp
Voltage Line: 4090 VAC 280 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 5.5 Vpp
Tx3 5.8 Vpp
Tx4 5.8 Vpp
Voltage Line: 4040 VAC 280 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 5.5 Vpp
Tx3 5.6 Vpp
Tx4 5.5 Vpp
Voltage Line: 4000 VAC 270 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
Tx3 5.7 Vpp
Tx4 5.6 Vpp
Voltage Line: 4030 VAC 280 KW
18:00 Driver 2 ON "IMAGING"
18:00 TX Power sample (-70 dB coupling)
Tx1 5.5 Vpp
Tx3 5.7 Vpp
Tx4 5.5 Vpp
Dr2 1.3 Vpp
Voltage Line: 4010 VAC 280 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 5.5 Vpp
Tx3 5.7 Vpp
Tx4 5.6 Vpp
Dr2 1.3 Vpp
Voltage Line: 4050 VAC 280 KW