Opened 6 years ago

Last modified 6 years ago

#369 new Transmitter

07 23 19:30 Transmitter Power Measurements

Reported by: ctipacti Owned by:
Priority: normal Milestone: 2018_07 Medium Power (EWDrift + Imaging)
Component: ISR+Imaging Version:
Keywords: Cc:

Description

07:55 LV ON
08:00 HV ON
08:21 TX Power sample (-70 dB coupling)
Dr2 1.45 Vpp
Dr4 1.42 Vpp
Voltage Line: 4130 VAC
09:00 TX Power sample (-70 dB coupling)
Dr2 1.46 Vpp
Dr4 1.41 Vpp
Voltage Line: 4130 VAC
10:00 TX Power sample (-70 dB coupling)
Dr2 1.47 Vpp
Dr4 1.42 Vpp
Voltage Line: 4150 VAC
11:00 TX Power sample (-70 dB coupling)
Dr2 1.42 Vpp
Dr4 1.41 Vpp
Voltage Line: 4100 VAC
12:00 TX Power sample (-70 dB coupling)
Dr2 1.43 Vpp
Dr4 1.42Vpp
Voltage Line: 4120 VAC
13:00 TX Power sample (-70 dB coupling)
Dr2 1.43 Vpp
Dr4 1.42 Vpp
Voltage Line: 4120 VAC
14:00 TX Power sample (-70 dB coupling)
Dr2 1.42 Vpp
Dr4 1.41 Vpp
Voltage Line: 4100 VAC
15:00 TX Power sample (-70 dB coupling)
Dr2 1.43 Vpp
Dr4 1.41 Vpp
Voltage Line: 4120 VAC
16:00 TX Power sample (-70 dB coupling)
Dr2 1.43 Vpp
Dr4 1.41 Vpp
Voltage Line: 4130 VAC
17:00 TX Power sample (-70 dB coupling)
Dr2 1.44 Vpp
Dr4 1.42 Vpp
Voltage Line: 4120 VAC
17:23 Driver 1 ON
18:00 TX Power sample (-70 dB coupling)
Dr1 1.39 Vpp
Dr2 1.44 Vpp
Dr4 1.42 Vpp
Voltage Line: 4120 VAC
19:00 TX Power sample (-70 dB coupling)
Dr1 1.37 Vpp
Dr2 1.40 Vpp
Dr4 1.39 Vpp
Voltage Line: 4100 VAC

Change History (1)

comment:1 Changed 6 years ago by imanay

  • Summary changed from 23 Jul 19:30 Transmitter Power Measurements to 07 23 19:30 Transmitter Power Measurements