Opened 6 years ago
Last modified 6 years ago
#353 new Transmitter
07 20 19:30 Transmitter Power Measurements
Reported by: | ctipacti | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2018_07 Medium Power (EWDrift + Imaging) |
Component: | ISR+Imaging | Version: | |
Keywords: | Cc: |
Description
08:00 TX Power sample (-70 dB coupling)
Dr2 1.43 Vpp
Dr4 1.43 Vpp
Line voltage 4120 VAC
09:00 TX Power sample (-70 dB coupling)
Dr2 1.43 Vpp
Dr4 1.43 Vpp
Line voltage 4120 VAC
10:00 TX Power sample (-70 dB coupling)
Dr2 1.44 Vpp
Dr4 1.42 Vpp
Line voltage 4120 VAC
11:00 TX Power sample (-70 dB coupling)
Dr2 1.44 Vpp
Dr4 1.42 Vpp
Line voltage 4120 VAC
12:00 TX Power sample (-70 dB coupling)
Dr2 1.45 Vpp
Dr4 1.42 Vpp
Line voltage 4120 VAC
13:00 TX Power sample (-70 dB coupling)
Dr2 1.45 Vpp
Dr4 1.42 Vpp
Line voltage 4120 VAC
14:00 TX Power sample (-70 dB coupling)
Dr2 1.44 Vpp
Dr4 1.42 Vpp
Line voltage 4100 VAC
15:00 TX Power sample (-70 dB coupling)
Dr2 1.45 Vpp
Dr4 1.42 Vpp
Line voltage 4120 VAC
16:00 TX Power sample (-70 dB coupling)
Dr2 1.45 Vpp
Dr4 1.42 Vpp
Line voltage 4120 VAC
17:00 TX Power sample (-70 dB coupling)
Dr2 1.44 Vpp
Dr4 1.42 Vpp
Line voltage 4120 VAC
17:20 D1 ON "IMAGING"
18:00 TX Power sample (-70 dB coupling)
Dr1 1.39 Vpp
Dr2 1.46 Vpp
Dr4 1.42 Vpp
Line voltage 4100 VAC
19:00 TX Power sample (-70 dB coupling)
Dr1 1.38 Vpp
Dr2 1.46 Vpp
Dr4 1.42 Vpp
Line voltage 4120 VAC
Change History (1)
comment:1 Changed 6 years ago by imanay
- Summary changed from 20 Jul 19:30 Transmitter Power Measurements to 07 20 19:30 Transmitter Power Measurements