Opened 6 years ago
Last modified 6 years ago
#336 new Transmitter
07 19 07:00 Transmitter Power Measurements
Reported by: | rtadeo | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2018_07 Medium Power (EWDrift + Imaging) |
Component: | ISR+Imaging | Version: | |
Keywords: | Cc: |
Description
20:00 TX Power sample (-70 dB coupling)
Dr1 1.39 Vpp
Dr2 1.48 Vpp
Dr4 1.42 Vpp
Voltage Line: 4120 VAC
21:00 TX Power sample (-70 dB coupling)
Dr1 1.39 Vpp
Dr2 1.46 Vpp
Dr4 1.42 Vpp
Voltage Line: 4120 VAC
22:00 TX Power sample (-70 dB coupling)
Dr1 1.40 Vpp
Dr2 1.50 Vpp
Dr4 1.42 Vpp
Voltage Line: 4140 VAC
23:00 TX Power sample (-70 dB coupling)
Dr1 1.40 Vpp
Dr2 1.50 Vpp
Dr4 1.42 Vpp
Voltage Line: 4140 VAC
19/07/2018
00:00 TX Power sample (-70 dB coupling)
Dr1 1.41 Vpp
Dr2 1.50 Vpp
Dr4 1.41 Vpp
Voltage Line: 4140 VAC
01:00 TX Power sample (-70 dB coupling)
Dr1 1.41 Vpp
Dr2 1.50 Vpp
Dr4 1.41 Vpp
Voltage Line: 4140 VAC
02:00 TX Power sample (-70 dB coupling)
Dr1 1.42 Vpp
Dr2 1.51 Vpp
Dr4 1.41 Vpp
Voltage Line: 4140 VAC
03:00 TX Power sample (-70 dB coupling)
Dr1 1.42 Vpp
Dr2 1.51 Vpp
Dr4 1.41 Vpp
Voltage Line: 4140 VAC
04:00 TX Power sample (-70 dB coupling)
Dr1 1.42 Vpp
Dr2 1.51 Vpp
Dr4 1.41 Vpp
Voltage Line: 4140 VAC
05:00 TX Power sample (-70 dB coupling)
Dr1 1.40 Vpp
Dr2 1.50 Vpp
Dr4 1.41 Vpp
Voltage Line: 4150 VAC
06:00 TX Power sample (-70 dB coupling)
Dr1 1.40 Vpp
Dr2 1.50 Vpp
Dr4 1.41 Vpp
Voltage Line: 4150 VAC
07:00 TX Power sample (-70 dB coupling)
Dr1 OFF IMAGING
Dr2 1.50 Vpp
Dr4 1.41 Vpp
Voltage Line: 4150 VAC
Change History (1)
comment:1 Changed 6 years ago by imanay
- Summary changed from 19 Jul 07:00 Transmitter Power Measurements to 07 19 07:00 Transmitter Power Measurements