07 18 07:08 Transmitter Power Measurements

Reported by: rtadeo Owned by:
Priority: normal Milestone: 2018_07 Medium Power (EWDrift + Imaging)
Component: ISR+Imaging Version:
Keywords: Cc:

Description

20:00 TX Power sample (-70 dB coupling)
Dr1 1.36 Vpp
Dr2 1.49 Vpp
Dr4 1.45 Vpp
Voltage Line: 4150 VAC
21:00 TX Power sample (-70 dB coupling)
Dr1 1.36 Vpp
Dr2 1.49 Vpp
Dr4 1.45 Vpp
Voltage Line: 4150 VAC
22:00 TX Power sample (-70 dB coupling)
Dr1 1.39 Vpp
Dr2 1.51 Vpp
Dr4 1.44 Vpp
Voltage Line: 4140 VAC
23:00 TX Power sample (-70 dB coupling)
Dr1 1.39 Vpp
Dr2 1.51 Vpp
Dr4 1.44 Vpp
Voltage Line: 4140 VAC
23:58 SCREEN OFF (FAILURE)
18/07/18
00:00 TX Power sample (-70 dB coupling)
Dr1 1.39 Vpp
Dr2 1.51 Vpp
Dr4 1.44 Vpp
Voltage Line: 4140 VAC
01:00 TX Power sample (-70 dB coupling)
Dr1 1.39 Vpp
Dr2 1.49 Vpp
Dr4 1.42 Vpp
Voltage Line: 4135 VAC
02:00 TX Power sample (-70 dB coupling)
Dr1 1.41 Vpp
Dr2 1.50 Vpp
Dr4 1.41 Vpp
Voltage Line: 4150 VAC
03:00 TX Power sample (-70 dB coupling)
Dr1 1.41 Vpp
Dr2 1.50 Vpp
Dr4 1.41 Vpp
Voltage Line: 4150 VAC
04:00 TX Power sample (-70 dB coupling)
Dr1 1.38 Vpp
Dr2 1.49 Vpp
Dr4 1.41 Vpp
Voltage Line: 4140 VAC
05:00 TX Power sample (-70 dB coupling)
Dr1 1.38 Vpp
Dr2 1.49 Vpp
Dr4 1.41 Vpp
Voltage Line: 4140 VAC
06:00 TX Power sample (-70 dB coupling)
Dr1 1.38 Vpp
Dr2 1.49 Vpp
Dr4 1.41 Vpp
Voltage Line: 4140 VAC
07:00 TX Power sample (-70 dB coupling)
Dr1 OFF IMAGING
Dr2 1.49 Vpp
Dr4 1.41 Vpp
Voltage Line: 4140 VAC

Change History (1)

comment:1 Changed 6 years ago by imanay

  • Summary changed from 18 Jul 07:08 Transmitter Power Measurements to 07 18 07:08 Transmitter Power Measurements