Opened 7 years ago
#267 new Transmitter
05 Apr 19:34 Transmitter Power Measurements
Reported by: | ctipacti | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2018_04 ISR + Imaging (HF Radar Campaign) |
Component: | ISR+Imaging | Version: | |
Keywords: | Cc: |
Description
08:00 TX Power sample (-70 dB coupling)
Tx1 5.72 Vpp
TX3 5.96 Vpp
TX4 5.32 Vpp
Voltage Line and Power: 4080 VAC, 280 Kw
09:00 TX Power sample (-70 dB coupling)
Tx1 5.58 Vpp
TX3 5.92 Vpp
TX4 5.28 Vpp
Voltage Line and Power: 4020 VAC, 280 Kw
10:00 TX Power sample (-70 dB coupling)
Tx1 5.60 Vpp
TX3 5.92 Vpp
TX4 5.32 Vpp
Voltage Line and Power: 4020 VAC, 280 Kw
11:00 TX Power sample (-70 dB coupling)
Tx1 5.60 Vpp
TX3 5.92 Vpp
TX4 5.32 Vpp
Voltage Line and Power: 4050 VAC, 280 Kw
12:00 TX Power sample (-70 dB coupling)
Tx1 5.56 Vpp
TX3 5.88 Vpp
TX4 5.32 Vpp
Voltage Line and Power: 4020 VAC, 280 Kw
13:00 TX Power sample (-70 dB coupling)
Tx1 5.52 Vpp
TX3 5.88 Vpp
TX4 5.36 Vpp
Voltage Line and Power: 4020 VAC, 280 Kw
14:00 TX Power sample (-70 dB coupling)
Tx1 5.52 Vpp
TX3 5.84 Vpp
TX4 5.28 Vpp
Voltage Line and Power: 4020 VAC, 280 Kw
15:00 TX Power sample (-70 dB coupling)
Tx1 5.60 Vpp
TX3 5.92 Vpp
TX4 5.36 Vpp
Voltage Line and Power: 4070 VAC, 280 Kw
16:00 TX Power sample (-70 dB coupling)
Tx1 5.56 Vpp
TX3 5.92 Vpp
TX4 5.36 Vpp
Voltage Line and Power: 4050 VAC, 280 Kw
17:00 TX Power sample (-70 dB coupling)
Tx1 5.60 Vpp
TX3 5.88 Vpp
TX4 5.32 Vpp
Voltage Line and Power: 4000 VAC, 280 Kw
17:05 D2 ON "IMAGING"
18:00 TX Power sample (-70 dB coupling)
Tx1 5.60 Vpp
TX3 5.88 Vpp
TX4 5.28 Vpp
D 2 1.27 Vpp
Voltage Line and Power: 4020 VAC, 280 Kw
19:00 TX Power sample (-70 dB coupling)
Tx1 5.64 Vpp
TX3 5.92 Vpp
TX4 5.36 Vpp
D 2 1.29 Vpp
Voltage Line and Power: 4080 VAC, 280 Kw