240	04 03 07:00 Transmitter Power Measurements	rtadeo		"20:00 TX Power sample (-70 dB coupling)
Tx1 5.64 Vpp
TX3 5.88 Vpp
TX4 5.52 Vpp
Dr2 1.28 Vpp
Voltage Line and Power: 4050 VAC, 290 Kw
21:00 TX Power sample (-70 dB coupling)
Tx1 5.64 Vpp
TX3 5.88 Vpp
TX4 5.52 Vpp
Dr2 1.28 Vpp
Voltage Line and Power: 4050 VAC, 290 Kw
22:00 TX Power sample (-70 dB coupling)
Tx1 5.60 Vpp
TX3 5.80 Vpp
TX4 5.48 Vpp
Dr2 1.30 Vpp
Voltage Line and Power: 4050 VAC, 290 Kw
23:00 TX Power sample (-70 dB coupling)
Tx1 5.60 Vpp
TX3 5.80 Vpp
TX4 5.48 Vpp
Dr2 1.30 Vpp
Voltage Line and Power: 4050 VAC, 290 Kw
00:00 TX Power sample (-70 dB coupling)
Tx1 5.60 Vpp
TX3 5.80 Vpp
TX4 5.48 Vpp
Dr2 1.30 Vpp
Voltage Line and Power: 4050 VAC, 290 Kw
01:00 TX Power sample (-70 dB coupling)
Tx1 5.56 Vpp
TX3 5.88 Vpp
TX4 5.48 Vpp
Dr2 1.30 Vpp
Voltage Line and Power: 4050 VAC, 290 Kw
02:00 TX Power sample (-70 dB coupling)
Tx1 5.56 Vpp
TX3 5.88 Vpp
TX4 5.48 Vpp
Dr2 1.30 Vpp
Voltage Line and Power: 4050 VAC, 290 Kw
03:00 TX Power sample (-70 dB coupling)
Tx1 5.56 Vpp
TX3 5.88 Vpp
TX4 5.48 Vpp
Dr2 1.30 Vpp
Voltage Line and Power: 4050 VAC, 290 Kw
03:08 Screen OFF TX1
04:00 TX Power sample (-70 dB coupling)
Tx1 5.56 Vpp
TX3 5.88 Vpp
TX4 5.48 Vpp
Dr2 1.30 Vpp
Voltage Line and Power: 4050 VAC, 290 Kw
05:00 TX Power sample (-70 dB coupling)
Tx1 5.56 Vpp
TX3 5.88 Vpp
TX4 5.48 Vpp
Dr2 1.30 Vpp
Voltage Line and Power: 4050 VAC, 290 Kw
06:00 TX Power sample (-70 dB coupling)
Tx1 5.56 Vpp
TX3 5.92 Vpp
TX4 5.52 Vpp
Dr2 1.32 Vpp
Voltage Line and Power: 4050 VAC, 290 Kw
06:55 Imaging OFF
07:00 TX Power sample (-70 dB coupling)
Tx1 5.60 Vpp
TX3 5.92 Vpp
TX4 5.48 Vpp
Voltage Line and Power: 4050 VAC, 290 Kw
"	Transmitter	new	normal	2018_04 ISR + Imaging (HF Radar Campaign)	ISR+Imaging				