Opened 4 years ago

#1655 new Transmitter

02 28 19:00 Transmitter Report

Reported by: vquesada Owned by:
Priority: normal Milestone: 2020_02 ISCOD Bubbles
Component: ISR Version:
Keywords: Cc:

Description

08:00 TX Power Sample (-70 dB coupling)
TX1 5.68 Vpp
TX3 5.96 Vpp
TX4 5.48 Vpp
Line Voltage 4040 VAC, 290 KW
09:00 TX Power Sample (-70 dB coupling)
TX1 5.68 Vpp
TX3 5.96 Vpp
TX4 5.48 Vpp
Line Voltage 4040 VAC, 290 KW
10:00 TX Power Sample (-70 dB coupling)
TX1 5.64 Vpp
TX3 5.96 Vpp
TX4 5.44 Vpp
Line Voltage 4040 VAC, 290 KW
11:00 TX Power Sample (-70 dB coupling)
TX1 5.64 Vpp
TX3 5.96 Vpp
TX4 5.44 Vpp
Line Voltage 4040 VAC, 290 KW
12:00 TX Power Sample (-70 dB coupling)
TX1 5.64 Vpp
TX3 5.96 Vpp
TX4 5.52 Vpp
Line Voltage 4080 VAC, 290 KW
13:00 TX Power Sample (-70 dB coupling)
TX1 5.64 Vpp
TX3 5.96 Vpp
TX4 5.52 Vpp
Line Voltage 4080 VAC, 290 KW
14:00 TX Power Sample (-70 dB coupling)
TX1 5.64 Vpp
TX3 5.96 Vpp
TX4 5.52 Vpp
Line Voltage 4080 VAC, 290 KW
15:00 TX Power Sample (-70 dB coupling)
TX1 5.64 Vpp
TX3 5.96 Vpp
TX4 5.52 Vpp
Line Voltage 4080 VAC, 290 KW
16:00 TX Power Sample (-70 dB coupling)
TX1 5.64 Vpp
TX3 5.96 Vpp
TX4 5.52 Vpp
Line Voltage 4050 VAC, 290 KW
17:00 TX Power Sample (-70 dB coupling)
TX1 5.64 Vpp
TX3 5.96 Vpp
TX4 5.52 Vpp
Line Voltage 4050 VAC, 290 KW
17:30 Driver 2 ON "Imaging"
18:00 TX Power Sample (-70 dB coupling)
TX1 5.64 Vpp
TX3 5.96 Vpp
TX4 5.52 Vpp
Dr2 1.32 Vpp
Line Voltage 4080 VAC, 290 KW
19:00 TX Power Sample (-70 dB coupling)
TX1 5.64 Vpp
TX3 5.96 Vpp
TX4 5.52 Vpp
Dr2 1.32 Vpp
Line Voltage 4080 VAC, 290 KW

Change History (0)

Note: See TracTickets for help on using tickets.