Opened 7 years ago

#159 new Transmitter

31 Jan 19:00 Transmitter Power Measurements

Reported by: rtadeo Owned by:
Priority: normal Milestone: 2018_01_1 ISCOD (Sudden Stratospheric Warming)
Component: ISR+Imaging Version:
Keywords: Cc:

Description

08:00 TX Power sample (-70 dB coupling)
Tx1 6.1 Vpp
Tx3 5.8 Vpp
Tx4 5.8 Vpp
Line voltage and power: 4070 VAC, 280 KW
09:00 TX Power sample (-70 dB coupling)
Tx1 6.1 Vpp
Tx3 5.8 Vpp
Tx4 5.8 Vpp
Line voltage and power: 4070 VAC, 280 KW
09:30 chance Atrs
10:15 TX Power sample (-70 dB coupling)
Tx1 5.61 Vpp
Tx3 5.41 Vpp
Tx4 5.36 Vpp
Line voltage and power: 4000 VAC, 250 KW
11:00 TX Power sample (-70 dB coupling)
Tx1 5.64 Vpp
Tx3 5.48 Vpp
Tx4 5.48 Vpp
Line voltage and power: 4050 VAC, 280 KW
12:00 TX Power sample (-70 dB coupling)
Tx1 5.64 Vpp
Tx3 5.48 Vpp
Tx4 5.48 Vpp
Line voltage and power: 4050 VAC, 280 KW
13:00 TX Power sample (-70 dB coupling)
Tx1 5.64 Vpp
Tx3 5.48 Vpp
Tx4 5.48 Vpp
Line voltage and power: 4050 VAC, 280 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 5.64 Vpp
Tx3 5.48 Vpp
Tx4 5.48 Vpp
Line voltage and power: 4000 VAC, 250 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 5.64 Vpp
Tx3 5.48 Vpp
Tx4 5.48 Vpp
Line voltage and power: 4000 VAC, 250 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 5.64 Vpp
Tx3 5.48 Vpp
Tx4 5.48 Vpp
Line voltage and power: 4040 VAC, 280 KW
17:08 PA1 rf (OFF Screen)
17:36 ON IMAGING
17:36 TX Power sample (-70 dB coupling)
Tx1 5.72 Vpp
Tx3 5.84 Vpp
Tx4 5.64 Vpp
Dr2 1.34 Vpp
Line voltage and power: 4000 VAC, 280 KW
18:00 TX Power sample (-70 dB coupling)
Tx1 5.72 Vpp
Tx3 5.84 Vpp
Tx4 5.64 Vpp
Dr2 1.34 Vpp
Line voltage and power: 4000 VAC, 280 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 5.72 Vpp
Tx3 5.84 Vpp
Tx4 5.64 Vpp
Dr2 1.34 Vpp
Line voltage and power: 4000 VAC, 280 KW

Change History (0)