Opened 5 years ago
#1521 new Transmitter
01 20 07:30 Transmitter report
Reported by: | ryaya | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2020_01 ICSOM-5 (ISR+Imaging) |
Component: | ISR+Imaging | Version: | |
Keywords: | Cc: |
Description
19/01/2020
21:00 TX Power sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Dr2 1.4 Vpp
Line voltage 4090 VAC, 290 KW
22:00 TX Power sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.8 Vpp
TX4 5.6 Vpp
Dr2 1.4 Vpp
Line voltage 4080 VAC, 290 KW
23:00 TX Power sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.7 Vpp
TX4 5.4 Vpp
Dr2 1.4 Vpp
Line voltage 4030 VAC, 290 KW
20/01/2020
00:00 TX Power sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Dr2 1.4 Vpp
Line voltage 4060 VAC, 290 KW
01:00 TX Power sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Dr2 1.4 Vpp
Line voltage 4030 VAC, 290 KW
02:00 TX Power sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.7 Vpp
TX4 5.5 Vpp
Dr2 1.4 Vpp
Line voltage 4040 VAC, 290 KW
03:00 TX Power sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.8 Vpp
TX4 5.5 Vpp
Dr2 1.4 Vpp
Line voltage 4070 VAC, 290 KW
04:00 TX Power sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.8 Vpp
TX4 5.6 Vpp
Dr2 1.4 Vpp
Line voltage 4060 VAC, 290 KW
05:00 TX Power sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.8 Vpp
TX4 5.5 Vpp
Dr2 1.4 Vpp
Line voltage 4020 VAC, 290 KW
05:40 Dr2 OFF
06:00 TX Power sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.8 Vpp
TX4 5.6 Vpp
Line voltage 4080 VAC, 290 KW
07:00 TX Power sample (-70 dB coupling)
TX1 6.0 Vpp
TX3 5.8 Vpp
TX4 5.6 Vpp
Line voltage 4100 VAC, 290 KW