﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
1491	01 17 07:15 Transmitter report	rtadeo		"
20:00 TX Power sample (-70 dB coupling)
TX1 5.92 Vpp
TX3 6.00 Vpp
TX4 5.48 Vpp
Dr2 1.44 Vpp
Line voltage 4060 VAC, 290 KW
21:00 TX Power sample (-70 dB coupling)
TX1 5.92 Vpp
TX3 6.00 Vpp
TX4 5.48 Vpp
Dr2 1.44 Vpp
Line voltage 4060 VAC, 290 KW
22:00 TX Power sample (-70 dB coupling)
TX1 5.92 Vpp
TX3 6.00 Vpp
TX4 5.48 Vpp
Dr2 1.44 Vpp
Line voltage 4060 VAC, 290 KW
23:00 TX Power sample (-70 dB coupling)
TX1 5.92 Vpp
TX3 6.00 Vpp
TX4 5.48 Vpp
Dr2 1.44 Vpp
Line voltage 4060 VAC, 290 KW
00:00 TX Power sample (-70 dB coupling)
TX1 5.92 Vpp
TX3 6.00 Vpp
TX4 5.48 Vpp
Dr2 1.44 Vpp
Line voltage 4060 VAC, 290 KW
01:00 TX Power sample (-70 dB coupling)
TX1 5.88 Vpp
TX3 6.00 Vpp
TX4 5.44 Vpp
Dr2 1.47 Vpp
Line voltage 4060 VAC, 290 KW
02:00 TX Power sample (-70 dB coupling)
TX1 5.88 Vpp
TX3 6.00 Vpp
TX4 5.44 Vpp
Dr2 1.47 Vpp
Line voltage 4060 VAC, 290 KW
03:00 TX Power sample (-70 dB coupling)
TX1 5.88 Vpp
TX3 6.00 Vpp
TX4 5.44 Vpp
Dr2 1.47 Vpp
Line voltage 4060 VAC, 290 KW
04:00 TX Power sample (-70 dB coupling)
TX1 5.88 Vpp
TX3 6.00 Vpp
TX4 5.44 Vpp
Dr2 1.47 Vpp
Line voltage 4060 VAC, 290 KW
05:00 TX Power sample (-70 dB coupling)
TX1 5.88 Vpp
TX3 5.92 Vpp
TX4 5.44 Vpp
Dr2 1.42 Vpp
Line voltage 4060 VAC, 290 KW
06:00 TX Power sample (-70 dB coupling)
TX1 5.88 Vpp
TX3 5.92 Vpp
TX4 5.44 Vpp
Dr2 1.42 Vpp
Line voltage 4060 VAC, 290 KW
06:00 Imaging OFF
07:00 TX Power sample (-70 dB coupling)
TX1 5.84 Vpp
TX3 6.04 Vpp
TX4 5.72 Vpp
Line voltage 4060 VAC, 290 KW
"	Transmitter	new	normal	2020_01 ICSOM-5 (ISR+Imaging)	ISR+Imaging				