Opened 5 years ago

#1489 new Transmitter

01 16 19:30 Transmitter report

Reported by: ryaya Owned by:
Priority: normal Milestone: 2020_01 ICSOM-5 (ISR+Imaging)
Component: ISR+Imaging Version:
Keywords: Cc:

Description

09:00 TX Power sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.9 Vpp
TX4 5.5 Vpp
Line voltage 4070 VAC, 280 KW
10:00 TX Power sample (-70 dB coupling)
TX1 5.7 Vpp
TX3 5.7 Vpp
TX4 5.3 Vpp
Line voltage 4000 VAC, 290 KW
10:26 RF OFF Adquisition adjustment
10:30 RF ON
11:00 TX Power sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.9 Vpp
TX4 5.6 Vpp
Line voltage 4060 VAC, 290 KW
12:00 TX Power sample (-70 dB coupling)
TX1 6.0 Vpp
TX3 6.0 Vpp
TX4 5.7 Vpp
Line voltage 4080 VAC, 290 KW
14:00 TX Power sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 6.0 Vpp
TX4 5.6 Vpp
Line voltage 4030 VAC, 290 KW
15:00 TX Power sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 6.0 Vpp
TX4 5.6 Vpp
Line voltage 4030 VAC, 290 KW
16:00 TX Power sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.9 Vpp
TX4 5.5 Vpp
Line voltage 4020 VAC, 290 KW
17:00 TX Power sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 6.0 Vpp
TX4 5.5 Vpp
Line voltage 4030 VAC, 290 KW
17:40 Driver 2 ON "IMAGING"
18:00 TX Power sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 6.0 Vpp
TX4 5.6 Vpp
Dr2 1.3 Vpp
Line voltage 4050 VAC, 290 KW
19:00 TX Power sample (-70 dB coupling)
TX1 6.0 Vpp
TX3 6.0 Vpp
TX4 5.6 Vpp
Dr2 1.4 Vpp
Line voltage 4060 VAC, 290 KW

Change History (0)

Note: See TracTickets for help on using tickets.