Opened 4 years ago

#1477 new Transmitter

01 14 19:22 Transmitter report

Reported by: ctipacti Owned by:
Priority: normal Milestone: 2020_01 ICSOM-5 (ISR+Imaging)
Component: ISR+Imaging Version:
Keywords: Cc:

Description

08:00 TX Power sample (-70 dB coupling)
TX1 5.88 Vpp
TX3 5.88 Vpp
TX4 5.44 Vpp
Line voltage 4050 VAC, 280 KW
09:00 TX Power sample (-70 dB coupling)
TX1 5.80 Vpp
TX3 5.88 Vpp
TX4 5.44 Vpp
Line voltage 4020 VAC, 280 KW
10:00 TX Power sample (-70 dB coupling)
TX1 5.80 Vpp
TX3 5.80 Vpp
TX4 5.44 Vpp
Line voltage 4000 VAC, 290 KW
10:45 PA3 screen failure
11:00 TX Power sample (-70 dB coupling)
TX1 5.80 Vpp
TX3 5.84 Vpp
TX4 5.44 Vpp
Line voltage 4020 VAC, 290 KW
12:00 TX Power sample (-70 dB coupling)
TX1 5.80 Vpp
TX3 5.88 Vpp
TX4 5.48 Vpp
Line voltage 4050 VAC, 290 KW
12:23 PA1 screen failure
14:00 TX Power sample (-70 dB coupling)
TX1 5.80 Vpp
TX3 5.88 Vpp
TX4 5.48 Vpp
Line voltage 4050 VAC, 290 KW
15:00 TX Power sample (-70 dB coupling)
TX1 5.80 Vpp
TX3 5.84 Vpp
TX4 5.48 Vpp
Line voltage 4020 VAC, 290 KW
16:00 TX Power sample (-70 dB coupling)
TX1 5.84 Vpp
TX3 5.88 Vpp
TX4 5.52 Vpp
Line voltage 4080 VAC, 290 KW
17:00 TX Power sample (-70 dB coupling)
TX1 5.80 Vpp
TX3 5.84 Vpp
TX4 5.48 Vpp
Line voltage 4020 VAC, 290 KW
17:33 Driver 2 ON "IMAGING"
18:00 TX Power sample (-70 dB coupling)
TX1 5.80 Vpp
TX3 5.88 Vpp
TX4 5.52 Vpp
Dr2 1.28 Vpp
Line voltage 4050 VAC, 290 KW
19:00 TX Power sample (-70 dB coupling)
TX1 5.80 Vpp
TX3 5.88 Vpp
TX4 5.52 Vpp
Dr2 1.28 Vpp
Line voltage 4050 VAC, 290 KW

Change History (0)