Opened 5 years ago

#1429 new Transmitter

12 04 19:30 Transmitter report

Reported by: ryaya Owned by:
Priority: normal Milestone: 2019_12 ISR+Imaging
Component: ISR+Imaging Version:
Keywords: Cc:

Description

09:00 TX Power sample (-70 dB coupling)
TX1 5.8 Vpp
TX3 5.7 Vpp
TX4 5.4 Vpp
Line voltage 4050 VAC, 290 KW
10:00 TX Power sample (-70 dB coupling)
TX1 5.84 Vpp
TX3 5.68 Vpp
TX4 5.36 Vpp
Line voltage 4050 VAC, 290 KW
11:00 TX Power sample (-70 dB coupling)
TX1 5.84 Vpp
TX3 5.68 Vpp
TX4 5.40 Vpp
Line voltage 4050 VAC, 290 KW
12:00 TX Power sample (-70 dB coupling)
TX1 5.88 Vpp
TX3 5.68 Vpp
TX4 5.44 Vpp
Line voltage 4080 VAC, 290 KW
14:00 Power sample (-70 dB coupling)
TX1 5.72 Vpp
TX3 5.68 Vpp
TX4 5.36 Vpp
Line voltage 4020 VAC, 290 KW
14:46 PA 4 control failure
15:00 Failure on Driver 4 bias power supply
16:00 TX Power sample (-70 dB coupling)
TX1 5.84 Vpp
TX3 5.64 Vpp
TX4 5.32 Vpp
Line voltage 4050 VAC, 290 KW
17:00 TX Power sample (-70 dB coupling)
TX1 5.88 Vpp
TX3 5.64 Vpp
TX4 5.32 Vpp
Line voltage 4020 VAC, 290 KW
17:14 Driver 2 ON
18:00 TX Power sample (-70 dB coupling)
TX1 5.88 Vpp
TX3 5.72 Vpp
TX4 5.32 Vpp
Dr2 1.32 Vpp
Line voltage 4090 VAC, 290 KW
19:00 TX Power sample (-70 dB coupling)
TX1 5.9 Vpp
TX3 5.72 Vpp
TX4 5.36 Vpp
Dr2 1.36 Vpp
Line voltage 4080 VAC, 290 KW