10 15 19:10 Transmitter Power Measurements
Reported by: | ctipacti | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2019_10 Hybrid |
Component: | ISR | Version: | |
Keywords: | Cc: |
Description
07:40 LV ON
08:00 HV ON
08:17 TX Power sample (-70 dB coupling)
Tx1 5.36 Vpp
Tx4 5.24 Vpp
Voltage Line: 4050 VAC, 230 Kw
09:00 TX Power sample (-73 dB coupling)
Tx1 3.80 Vpp
Tx4 3.84 Vpp
Voltage Line: 4080 VAC, 240 Kw
09:09 PA 1 Screen power supply failure
10:00 TX Power sample (-73 dB coupling)
Tx1 3.80 Vpp
Tx4 3.88 Vpp
Voltage Line: 4050 VAC, 240 Kw
11:00 TX Power sample (-73 dB coupling)
Tx1 3.80 Vpp
Tx4 3.88 Vpp
Voltage Line: 4080 VAC, 240 Kw
12:00 TX Power sample (-73 dB coupling)
Tx1 3.80 Vpp
Tx4 3.88 Vpp
Voltage Line: 4080 VAC, 240 Kw
14:00 TX Power sample (-73 dB coupling)
Tx1 3.80 Vpp
Tx4 3.88 Vpp
Voltage Line: 4080 VAC, 240 Kw
15:00 TX Power sample (-73 dB coupling)
Tx1 3.80 Vpp
Tx4 3.88 Vpp
Voltage Line: 4080 VAC, 240 Kw
16:00 TX Power sample (-73 dB coupling)
Tx1 3.80 Vpp
Tx4 3.84 Vpp
Voltage Line: 4050 VAC, 240 Kw
17:00 TX Power sample (-73 dB coupling)
Tx1 3.80 Vpp
Tx4 3.88 Vpp
Voltage Line: 4050 VAC, 240 Kw
18:00 TX Power sample (-73 dB coupling)
Tx1 3.80 Vpp
Tx3 3.84 Vpp
Voltage Line: 4050 VAC, 240Kw
19:00 TX Power sample (-73 dB coupling)
Tx1 3.80 Vpp
Tx3 3.84 Vpp
Voltage Line: 4050 VAC, 240 Kw