Opened 5 years ago
#1316 new Transmitter
10 01 19:20 Transmitter Power Measurements
Reported by: | ctipacti | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2019_10 High Altitude Drifts |
Component: | ISR | Version: | |
Keywords: | Cc: |
Description
07:50 LV ON
08:04 HV ON
08:23 TX Power sample (-70 dB coupling)
TX1 5.20 Vpp
TX4 5.20 Vpp
Line voltage 4050 VAC, 310 KW
09:00 TX Power sample (-70 dB coupling)
TX1 5.28 Vpp
TX4 5.32 Vpp
Line voltage 4080 VAC, 310 KW
10:00 TX Power sample (-70 dB coupling)
TX1 5.28 Vpp
TX4 5.32 Vpp
Line voltage 4080 VAC, 300 KW
11:00 TX Power sample (-70 dB coupling)
TX1 5.28 Vpp
TX4 5.32 Vpp
Line voltage 4050 VAC, 300 KW
12:00 TX Power sample (-70 dB coupling)
TX1 5.28 Vpp
TX4 5.24 Vpp
Line voltage 4080 VAC, 300 KW
14:00 TX Power sample (-70 dB coupling)
TX1 5.20 Vpp
TX4 5.20 Vpp
Line voltage 4050 VAC, 300 KW
15:00 TX Power sample (-70 dB coupling)
TX1 5.20 Vpp
TX4 5.20 Vpp
Line voltage 4080 VAC, 300 KW
16:00 TX Power sample (-70 dB coupling)
TX1 5.20 Vpp
TX4 5.14 Vpp
Line voltage 4020 VAC, 300 KW
17:00 TX Power sample (-70 dB coupling)
TX1 5.10 Vpp
TX4 5.14 Vpp
Line voltage 4020 VAC, 300 KW
18:00 TX Power sample (-70 dB coupling)
TX1 5.20 Vpp
TX4 5.20 Vpp
Line voltage 4050 VAC, 300 KW
19:00 TX Power sample (-70 dB coupling)
TX1 5.20 Vpp
TX4 5.20 Vpp
Line voltage 4050 VAC, 300 KW