Opened 5 years ago
#1279 new Transmitter
09 27 19:20 Transmitter power measurements
Reported by: | ctipacti | Owned by: | |
---|---|---|---|
Priority: | normal | Milestone: | 2019_09 ISCOD (ISR+Imaging) |
Component: | ISR+Imaging | Version: | |
Keywords: | Cc: |
Description
09:00 TX Power sample (-70 dB coupling)
TX1 5.84 Vpp
Line voltage 4080 VAC, 220 KW
10:00 TX Power sample (-70 dB coupling)
TX1 5.84 Vpp
Line voltage 4100 VAC, 220 KW
11:00 TX Power sample (-70 dB coupling)
TX1 5.88 Vpp
Line voltage 4050 VAC, 220 KW
12:00 TX Power sample (-70 dB coupling)
TX1 5.84 Vpp
Line voltage 4080 VAC, 220 KW
13:00 TX Power sample (-70 dB coupling)
TX1 5.88 Vpp
Line voltage 4050 VAC, 220 KW
14:00 TX Power sample (-70 dB coupling)
TX1 5.72 Vpp
Line voltage 4000 VAC, 220 KW
15:00 TX Power sample (-70 dB coupling)
TX1 5.84 Vpp
Line voltage 4050 VAC, 220 KW
16:00 TX Power sample (-70 dB coupling)
TX1 5.84 Vpp
Line voltage 4050 VAC, 220 KW
17:00 TX Power sample (-70 dB coupling)
TX1 5.88 Vpp
Line voltage 4080 VAC, 220 KW
17:10 Dr2 ON "Imaging"
18:00 TX Power sample (-70 dB coupling)
TX1 5.84 Vpp
Dr2 1.30 Vpp
Line voltage 4050 VAC, 220 KW
19:00 TX Power sample (-70 dB coupling)
TX1 5.84 Vpp
Dr2 1.30 Vpp
Line voltage 4050 VAC, 220 KW