﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
1274	09 26 19:40 Transmitter report	ryaya		"08:30 Internal arcing detected on TX3.
08:40 Tx configuration changed to operate with TX1 and Dr2
10:00 RF OFF, problem on RX system
11:55 RF ON
TX1 5.9 Vpp
Dr2 1.2 Vpp (Test Imaging)
12:15 Dr2 OFF
14:00 TX Power sample (-70 dB coupling)
TX1 5.9 Vpp
Line voltage 4060 VAC, 220 KW
15:00 TX Power sample (-70 dB coupling)
TX1 5.9 Vpp
Line voltage 4080 VAC, 220 KW
16:00 TX Power sample (-70 dB coupling)
TX1 5.9 Vpp
Line voltage 4080 VAC, 220 KW
16:45 Dr2 ON ""Imaging""
17:00 TX Power sample (-70 dB coupling)
TX1 5.8 Vpp
Dr2 1.3
Line voltage 4060 VAC, 220 KW
18:00 TX Power sample (-70 dB coupling)
TX1 5.8 Vpp
Dr2 1.27 Vpp
Line voltage 4050 VAC, 220 KW
19:00 TX Power sample (-70 dB coupling)
TX1 5.7 Vpp
Dr2 1.3 Vpp
Line voltage 4030 VAC, 220 KW"	Transmitter	new	normal	2019_09 ISCOD (ISR+Imaging)	ISR+Imaging				
