﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
1243	09 11 19:20 Transmitter power measurements	ctipacti		"09:00 TX Power sample (-70 dB coupling)
TX1 6.1 Vpp
TX4 6.1 Vpp
Line voltage 4100 VAC, 170 KW
10:00 TX Power sample (-70 dB coupling)
TX1 6.1 Vpp
TX4 5.2 Vpp
Line voltage 4080 VAC, 170 KW
11:00 TX Power sample (-70 dB coupling)
TX1 6.0 Vpp
TX4 6.2 Vpp
Line voltage 4050 VAC, 170 KW
12:00 TX Power sample (-70 dB coupling)
TX1 6.0 Vpp
TX4 6.1 Vpp
Line voltage 4050 VAC, 170 KW
14:00 TX Power sample (-70 dB coupling)
TX1 5.9 Vpp
TX4 6.1 Vpp
Line voltage 4050 VAC, 170 KW
14:10 RF OFF (Reception failure)
14:28 RF ON
15:00 TX Power sample (-70 dB coupling)
TX1 6.1 Vpp
TX4 6.1 Vpp
Line voltage 4050 VAC, 170 KW
16:00 TX Power sample (-70 dB coupling)
TX1 6.1 Vpp
TX4 6.1 Vpp
Line voltage 4080 VAC, 170 KW
17:00 RF OFF (Change HDD of acquisition system)
17:03 RF ON
17:05 TX Power sample (-70 dB coupling)
TX1 6.0 Vpp
TX4 6.1 Vpp
Line voltage 4050 VAC, 170 KW
18:00 TX Power sample (-70 dB coupling)
TX1 6.1 Vpp
TX4 6.2 Vpp
Line voltage 4080 VAC, 170 KW
19:00 TX Power sample (-70 dB coupling)
TX1 6.1 Vpp
TX4 6.2 Vpp
Line voltage 4050 VAC, 170 KW"	Transmitter	new	normal	2019_09 Winds	ISR				