1173	08 06 17:30 Transmitter Power Measurements	rtadeo		"07:50 LV ON
08:00 HV ON
08:00 TX Power sample (-70 dB coupling)
Tx3 5.12 Vpp
Tx4 5.00 Vpp 
Line voltage AC 4030 VAC 310 KW
09:00 TX Power sample (-70 dB coupling)
Tx3 5.16 Vpp
Tx4 5.04 Vpp 
Line voltage AC 4020 VAC 310 KW
10:00 TX Power sample (-70 dB coupling)
Tx3 5.16 Vpp
Tx4 5.08 Vpp 
Line voltage AC 4050 VAC 310 KW
11:00 TX Power sample (-70 dB coupling)
Tx3 5.28 Vpp
Tx4 5.12 Vpp 
Line voltage AC 4050 VAC 320 KW
12:00 TX Power sample (-70 dB coupling)
Tx3 5.24 Vpp
Tx4 5.16 Vpp 
Line voltage AC 4090 VAC 320 KW
13:00 TX Power sample (-70 dB coupling)
Tx3 5.24 Vpp
Tx4 5.16 Vpp 
Line voltage AC 4050 VAC 310 KW
14:00 TX Power sample (-70 dB coupling)
Tx3 5.24 Vpp
Tx4 5.16 Vpp 
Line voltage AC 4010 VAC 310 KW
15:00 TX Power sample (-70 dB coupling)
Tx3 5.24 Vpp
Tx4 5.08 Vpp 
Line voltage AC 4010 VAC 310 KW
16:00 TX Power sample (-70 dB coupling)
Tx3 5.32 Vpp
Tx4 5.12 Vpp 
Line voltage AC 4010 VAC 310 KW
17:00 TX Power sample (-70 dB coupling)
Tx3 5.24 Vpp
Tx4 5.12 Vpp 
Line voltage AC 4010 VAC 310 KW
17:30 OFF TX (end of stream)"	Transmitter	new	normal	2019_08 Plasma Frequency (JRO&Sousy)	ISR				