Opened 7 years ago

Last modified 7 years ago

#115 new Transmitter

28 Jan 19:20 Transmitter report

Reported by: ryaya Owned by:
Priority: normal Milestone: 2018_01_1 ISCOD (Sudden Stratospheric Warming)
Component: ISR+Imaging Version:
Keywords: Cc:

Description

09:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.8 Vpp
Tx4 6.0 Vpp
Line voltage and power: 4020 VAC, 280 KW
10:00 TX Power sample (-70 dB coupling)
Tx1 6.1 Vpp
Tx3 6.0 Vpp
Tx4 6.0 Vpp
Line voltage and power: 4000 VAC, 280 KW
11:00 TX Power sample (-70 dB coupling)
Tx1 6.3 Vpp
Tx3 6.1 Vpp
Tx4 6.2 Vpp
Line voltage and power: 4060 VAC, 280 KW
12:00 TX Power sample (-70 dB coupling)
Tx1 6.0 Vpp
Tx3 5.6 Vpp
Tx4 5.7 Vpp
Line voltage and power: 4050 VAC, 280 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.5 Vpp
Tx4 5.7 Vpp
Line voltage and power: 4020 VAC, 280 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
Tx3 5.5 Vpp
Tx4 5.6 Vpp
Line voltage and power: 4000 VAC, 280 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp
Tx3 5.6 Vpp
Tx4 5.8 Vpp
Line voltage and power: 4020 VAC, 280 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.6 Vpp
Tx4 5.7 Vpp
Line voltage and power: 4000 VAC, 280 KW
17:29 D2 On "IMAGING"
18:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp
Tx3 5.5 Vpp
Tx4 5.6 Vpp
D2 1.3 Vpp
Line voltage and power: 4000 VAC, 280 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 5.6 Vpp
Tx3 5.5 Vpp
Tx4 5.6 Vpp
D2 1.3 Vpp
Line voltage and power: 4030 VAC, 280 KW

Change History (1)

comment:1 Changed 7 years ago by ryaya

  • Component changed from ISR to ISR+Imaging
Note: See TracTickets for help on using tickets.