109	27 Jan 19:20 Transmitter report	ryaya		"09:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp 
Tx3 5.7 Vpp
Tx4 5.8 Vpp
Line voltage and power: 4050 VAC, 280 KW
09:10 CROWBAR, Main power supply failure
09:38 HV OFF, ATR replacement
11:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp 
Tx3 5.5 Vpp
Tx4 5.6 Vpp
Line voltage and power: 4000 VAC, 280 KW
12:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp 
Tx3 5.6 Vpp
Tx4 5.8 Vpp
Line voltage and power: 4080 VAC, 280 KW
14:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp 
Tx3 5.6 Vpp
Tx4 5.8 Vpp
Line voltage and power: 4000 VAC, 280 KW
15:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp 
Tx3 5.6 Vpp
Tx4 5.8 Vpp
Line voltage and power: 4050 VAC, 280 KW
16:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp 
Tx3 5.6 Vpp
Tx4 5.7 Vpp
Line voltage and power: 4040 VAC, 280 KW
17:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp 
Tx3 5.6 Vpp
Tx4 5.8 Vpp
Line voltage and power: 4010 VAC, 280 KW
17:40 D2 On ""IMAGING""
18:00 TX Power sample (-70 dB coupling)
Tx1 5.7 Vpp 
Tx3 5.7 Vpp
Tx4 5.7 Vpp
D2 1.3 Vpp
Line voltage and power: 4000 VAC, 280 KW
19:00 TX Power sample (-70 dB coupling)
Tx1 5.8 Vpp 
Tx3 5.6 Vpp
Tx4 5.8 Vpp
D2 1.3 Vpp
Line voltage and power: 4080 VAC, 280 KW"	Transmitter	new	normal	2018_01_1 ISCOD (Sudden Stratospheric Warming)	ISR+Imaging				