﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
1094	07 02 07:30 Transmitter power measurement	rtadeo		"
20:00 TX Power sample (-70 dB coupling)
TX1 5.48 Vpp
TX3 3.84 Vpp
TX4 3.84 Vpp
Dr2 1.30 Vpp
Line voltage 4050 VAC, 330 KW
21:00 TX Power sample (-70 dB coupling)
TX1 5.48 Vpp
TX3 3.84 Vpp
TX4 3.84 Vpp
Dr2 1.30 Vpp
Line voltage 4050 VAC, 330 KW
22:00 TX Power sample (-70 dB coupling)
TX1 5.48 Vpp
TX3 3.64 Vpp
TX4 3.64 Vpp
Dr2 1.30 Vpp
Line voltage 4050 VAC, 330 KW
23:00 TX Power sample (-70 dB coupling)
TX1 5.52 Vpp
TX3 3.82 Vpp
TX4 3.82 Vpp
Dr2 1.40 Vpp
Line voltage 4050 VAC, 330 KW
00:00 TX Power sample (-70 dB coupling)
TX1 5.52 Vpp
TX3 3.80 Vpp
TX4 3.80 Vpp
Dr2 1.40 Vpp
Line voltage 4050 VAC, 330 KW
01:00 TX Power sample (-70 dB coupling)
TX1 5.52 Vpp
TX3 3.80 Vpp
TX4 3.80 Vpp
Dr2 1.40 Vpp
Line voltage 4050 VAC, 330 KW
02:00 TX Power sample (-70 dB coupling)
TX1 5.52 Vpp
TX3 3.80 Vpp
TX4 3.80 Vpp
Dr2 1.40 Vpp
Line voltage 4050 VAC, 330 KW
03:00 TX Power sample (-70 dB coupling)
TX1 5.52 Vpp
TX3 3.80 Vpp
TX4 3.80 Vpp
Dr2 1.40 Vpp
Line voltage 4050 VAC, 330 KW
04:00 TX Power sample (-70 dB coupling)
TX1 5.32 Vpp
TX3 3.84 Vpp
TX4 3.84 Vpp
Dr2 1.43 Vpp
Line voltage 4050 VAC, 330 KW
05:00 TX Power sample (-70 dB coupling)
TX1 5.32 Vpp
TX3 3.84 Vpp
TX4 3.84 Vpp
Dr2 1.43 Vpp
Line voltage 4050 VAC, 330 KW
06:00 TX Power sample (-70 dB coupling)
TX1 5.32 Vpp
TX3 3.84 Vpp
TX4 3.84 Vpp
Dr2 1.43 Vpp
Line voltage 4060 VAC, 310 KW
06:40 OFF iMAGING
07:00 TX Power sample (-70 dB coupling)
TX1 5.36 Vpp
TX3 3.80 Vpp
TX4 3.80 Vpp
Line voltage 4050 VAC, 330 KW"	Transmitter	new	normal	2019_07 Eclipse	ISR+Imaging				